Cross-Connection Control and Backflow Prevention
Upcoming dates (2)
Fee
- $1,295
-
Fee covers morning and afternoon breaks, scheduled lunches, course materials.
ID
RA00447-D378
Credits
- CEU: 4
- PDH: 40
Schedule
Registration Date/Time:
10/21/2024 7:30am Central Time
Event Dates/Times:
- 10/21/2024 8:00am - 5:00pm Central Time
- 10/22/2024 7:30am - 5:00pm Central Time
- 10/23/2024 7:30am - 5:00pm Central Time
- 10/24/2024 7:30am - 5:00pm Central Time
- 10/25/2024 7:00am - 3:00pm Central Time
Instructors
Roy Curtis Thompson, Benjamin Jordan, Charles Kraege-Soechting
Location
MADISON AREA TECHNICAL COLLEGE
Commercial Ave Education Center2125 Commercial Ave
Madison, WI 53704
Accommodations
Room: rates start at $98
Group Code: 90J
Reserve by: Sep. 19, 2024
Cancellation Policy
If you cannot attend, please notify us by no later than one week before your course begins, and we will refund your fee. Because this course has limited enrollment, cancellation received after this date and no-shows are subject to the full course fee. You may enroll a substitute at any time before the course starts.
Course Overview
- Fulfill backflow prevention tester training requirements
- Understand cross-connection and backflow hazards
- Select the right backflow prevention assembly for each application
- Test and repair backflow prevention assemblies hands on
Who Should Attend?
Practical training for plumbers, sprinkler fitters, facility maintenance personnel, and utility workers focusing on procedures for cross-connection control, backflow prevention, and testing of backflow prevention assemblies.
Additional Information
Fulfill Registration and Certification Requirements
Participation in this course and successful completion of the hands-on and written examinations qualifies for 40 professional development hours (PDH) or 4.0 continuing education units (CEU).
Wisconsin: Successful completion of the Cross-Connection Control and Backflow Prevention course and exam fulfills the training requirements in Wisconsin for Cross-Connection Control Tester registration and is also approved for 40 Wisconsin Department of Safety and Professional Services continuing education hours for many plumbing and fire sprinkler related credentials.
Minnesota and Michigan: ASSE certification is required. To earn ASSE Backflow Prevention Assembly Tester certification, you must register for the ASSE Backflow Prevention Assembly Tester course and exam.
Course Outline
Day 1
Introduction to Cross-Connection Control and Backflow Prevention
Cross-connection basics
- Hazards to public health
- Causes of backflow
Backflow Prevention Methods
- Air gap
- Barometric loop
Backflow Prevention Assemblies—Double Check Valve Assembly (DC)
- How the Double Check Valve Assembly works
- Appropriate application of the Double Check Valve
- Assembly limitations
Testing of Backflow Prevention Assemblies
- 3-valve and 5-valve test gauges
- Care and maintenance of test gauges
- Calibration requirements
Workshop
- Demonstration of proper testing practices
- Demonstration of Double Check Valve (DC) assembly test procedures
- Hands-on practice with DC testing
Day 2
Quiz
Backflow Prevention Assemblies
- Reduced Pressure Principal Assembly (RPZ)
- How the Reduced Pressure Principal Assembly works
- Appropriate application of the RPZ
- Pressure vacuum breaker (PVB) and Spill-resistant vacuum breaker (SVB)
- How the PVB and SVB work
- Appropriate application and limitations of the PVB and SVB
Workshop
- Test procedures for reduced pressure principle (RPZ), spill-resistant vacuum breaker (SVB), and pressure vacuum breaker (PVB) assemblies
- Hands-on Practice – all testable assembly types
Day 3
Backflow Prevention Devices
- Appropriate device applications
- Limitations of devices
Cross-Connection Program Authority, Responsibility, and Liability
- Federal authority
- State responsibilities
- Municipality or water purveyor responsibilities
- Designer, installer, and manufacturer responsibilities
- Facility owner responsibilities
- Liability issues
Safety
- How to minimize hazards for testers
- Personal protective equipment
- Confined space, lockout/tagout, fall-prevention
Quiz
Day 4
Wisconsin Rules and Codes
- Rules and regulations
- Requirements for new and existing services
Municipal and Utility Cross-Connection Programs
- How to establish a utility cross-connection control program
- Cross-connection survey programs
- How to manage cross-connection programs—documentation, tracking, and follow-up
Troubleshooting Reduced Pressure Principle Backflow Preventers
- How to relate malfunction symptoms to cause
- Repair of backflow preventers
- Hands-on troubleshooting and discussion
Troubleshooting Workshop—Hands-On Practice Classroom
Review Session
Individual Hands-On Practical Exams
Day 5
Individual Hands-On Practical Exams Continue
Manufacturer Presentations
- Discussion of backflow prevention assemblies from various manufacturers
Written Exams
Testimonials
"Phenomenal class! Should be mandatory for everyone... went above and beyond my expectations. I will be a stronger asset to my company because of this class."
"One of the best classes I have been to in the last 20 years."
"Every journeyman or master plumber should attend the class."
"Great course, very informative, a lot of fun, instructors did a great job of keeping me involved and comfortable."
Instructors
Benjamin Jordan
Benjamin J. Jordan, PE is a program director with Interdisciplinary Professional Programs in the transportation sector. He has over 35 years of experience in civil engineering and public works. He earned a Bachelor of Science Degree in Civil Engineering from the University of Illinois at Urbana–Champaign and a Master of Public Affairs degree with a Certificate in Public Management from the University of Missouri-Columbia. He is a Licensed Professional Engineer in the State of Illinois.
Roy Curtis Thompson
Charles Kraege-Soechting
Cross-Connection Control and Backflow Prevention
Location: Madison, WI
Course #: RA00447-D378
Fee: $1,295
Fee
- $1,295
-
Fee covers morning and afternoon breaks, scheduled lunches, course materials.
Credits
- CEU: 4
- PDH: 40
Schedule
Registration Date/Time:
10/21/2024 7:30am Central Time
Event Dates/Times:
- 10/21/2024 8:00am - 5:00pm Central Time
- 10/22/2024 7:30am - 5:00pm Central Time
- 10/23/2024 7:30am - 5:00pm Central Time
- 10/24/2024 7:30am - 5:00pm Central Time
- 10/25/2024 7:00am - 3:00pm Central Time
Instructors
Roy Curtis Thompson, Benjamin Jordan, Charles Kraege-Soechting
Location
MADISON AREA TECHNICAL COLLEGE
Commercial Ave Education Center2125 Commercial Ave
Madison, WI 53704
Accommodations
Room: rates start at $98
Group Code: 90J
Reserve by: Sep. 19, 2024
Cancellation Policy
If you cannot attend, please notify us by no later than one week before your course begins, and we will refund your fee. Because this course has limited enrollment, cancellation received after this date and no-shows are subject to the full course fee. You may enroll a substitute at any time before the course starts.
Cross-Connection Control and Backflow Prevention
Location: Madison, WI
Course #: RA00447-D384
Fee: $1,295
Fee
- $1,295
-
Fee covers morning and afternoon breaks, scheduled lunches, course materials.
Credits
- CEU: 4
- PDH: 40
Schedule
Registration Date/Time:
3/24/2025 7:30am Central Time Zone
Event Dates/Times:
- 3/3/2025 8:00am - 5:00pm Central Time Zone
- 3/4/2025 7:30am - 5:00pm Central Time Zone
- 3/5/2025 7:30am - 5:00pm Central Time Zone
- 3/6/2025 7:30am - 5:00pm Central Time Zone
- 3/7/2025 7:00am - 3:00pm Central Time Zone
Instructor
Benjamin Jordan
Location
MADISON AREA TECHNICAL COLLEGE
Commercial Ave Education Center2125 Commercial Ave
Madison, WI 53704
Accommodations
Room: rates start at $98
Reserve by: Jan. 30, 2025
Cancellation Policy
If you cannot attend, please notify us by no later than one week before your course begins, and we will refund your fee. Because this course has limited enrollment, cancellation received after this date and no-shows are subject to the full course fee. You may enroll a substitute at any time before the course starts.
Cross-Connection Control and Backflow Prevention
Course #: RA00447Cross-Connection Control and Backflow Prevention
Date: Mon. June 03, 2024 – Fri. June 07, 2024ID: RA00447-D368
Fee:
- $1,295
- Fee covers morning and afternoon breaks, scheduled lunches, course materials.
- CEU: 4
- PDH: 40
Commercial Ave Education Center
2125 Commercial Ave
Madison, WI 53704
Cross-Connection Control and Backflow Prevention
Date: Mon. March 11, 2024 – Fri. March 15, 2024ID: RA00447-D262
Fee:
- $1,295
- Fee covers morning and afternoon breaks, scheduled lunches, course materials.
- CEU: 4
- PDH: 40
Cross-Connection Control and Backflow Prevention
Date: Mon. October 23, 2023 – Fri. October 27, 2023ID: RA00447-C961
Fee:
- $1,295
- Fee covers morning and afternoon breaks, scheduled lunches, course materials.
- CEU: 4
- PDH: 40
Cross-Connection Control and Backflow Prevention
Date: Mon. March 20, 2023 – Fri. March 24, 2023ID: RA00447-C245
Fee:
- $1,295
-
Fee covers breakfast, refreshment breaks, lunch will be provided all five days and course materials.
- CEU: 4
- PDH: 40
Cross-Connection Control and Backflow Prevention
Date: Mon. October 24, 2022 – Fri. October 28, 2022ID: RA00447-U353
Fee:
- $1,295
-
Fee covers breakfast, refreshment breaks, lunch will be provided all five days and course materials.
- CEU: 4
- PDH: 40
Create a custom learning experience
We can deliver this course as an on-site learning experience tailored to your organization’s specific training needs.
On-site / Customizable
We Bring It to You
Build a tighter team with an on-site training course. Choose from our most popular topics. We’ll create a collaborative experience based on your class size and specifications.
We Build It for You
Shape a course to meet your specific training needs. Add specialized topics and technology. Tweak the course materials. Make it yours. We’ll make it possible.
We Create It With You
Start from scratch with an unbiased analysis of your company’s training needs. We’ll help you pinpoint opportunities and develop a smart program for your in-house talent.